Frequently Asked
Questions

What is the LuminEV Research Kit?

LuminEV is a multiplex bead-based immunoassay that measures the tetraspanins CD9, CD63 and CD81 on intact extracellular vesicles (EVs) directly in unprocessed human plasma and cell culture media, without EV isolation. It runs on Luminex xMAP instruments in a 96-well format. It is developed and manufactured by NeuroDex, Inc. in Natick, Massachusetts. See the full specifications.

Which EV markers does LuminEV measure?

The standard kit measures CD9, CD63 and CD81, the three tetraspanins most widely used as EV markers. Each well also includes a capture control bead to measure non-specific signal. Custom panels with other EV surface proteins are available on request.

Do I need to isolate EVs before running LuminEV?

No. LuminEV measures EV surface proteins directly in plasma and cell culture media, so there is no ultracentrifugation, size-exclusion chromatography or precipitation step. Skipping isolation saves time and sample, and avoids the vesicle loss and method-dependent bias that isolation steps introduce.

Which sample types are validated?

The assay is validated for human K2EDTA plasma and cell culture media. Purified EVs can also be measured. For other biofluids, contact our scientific support team before starting.

How much sample do I need?

Each well takes 50 µL of diluted sample. For plasma, the recommended starting dilution is 1:4, which corresponds to about 12.5 µL of neat plasma per well. Cell culture media dilution depends on the cell type.

How should I prepare plasma samples?

Collect blood into K2EDTA tubes, centrifuge the plasma at 5,000 × g for 10 minutes to remove clots and debris, and dilute 1:4 in assay diluent as a starting point. Plasma was stable for up to three freeze-thaw cycles in validation, but repeated freeze-thaw cycles should be avoided because they can reduce sensitivity.

How should I prepare cell culture media?

Filter conditioned media through a filter plate before testing, as described in the assay manual. No EV concentration step is needed: in the validation study, LuminEV detected EVs in conditioned media from 15 different cell lines without prior concentration.

What instrument do I need?

A Luminex xMAP instrument: Luminex 200, FLEXMAP 3D or MAGPIX (xPONENT software), or xMAP INTELLIFLEX. You also need a magnetic plate washer or handheld magnetic separator, a plate shaker, sheath fluid, PBS-T wash buffer and 96-well plates. A standard fluorescence plate reader cannot read the assay.

How long does the assay take?

About 1 hour 45 minutes of hands-on time, with results in about 24 hours. Most of that time is an overnight incubation (16–20 hours at 4 °C), followed by a 2-hour detection step and a 20-minute streptavidin-PE step.

How sensitive is LuminEV, and what is the assay range?

Analytical sensitivity is 10 ng/mL, and the assay range is 30 ng/mL to 30 µg/mL, which may vary between lots. Concentrations are calculated against an EV standard curve.

How precise and reproducible is the assay?

Coefficients of variation (CV) are below 15% within the validated dilution range. The assay was validated for agreement between simplex and multiplex measurements, linearity, spike-in recovery, intra- and inter-assay precision, and reproducibility between operators.

What standard does the kit use?

The kit includes an EV standard made from purified EVs of cultured human cells (HEK293). The standard is run as a 7-point curve from 0.1 to 100 µg/mL, and sample EV marker concentrations are calculated from it.

What is included in the kit?

Capture beads for CD9, CD63 and CD81, capture control beads, a detection antibody cocktail, the EV standard, streptavidin-PE conjugate and assay diluent. The Luminex instrument, sheath fluid, wash buffer, plates and magnetic washer are not included.

How is the kit shipped and stored?

The kit ships on blue ice (4 °C). Store the reagents at 4 °C and the EV standard at −80 °C. Use all reagents before the expiration date printed for your lot.

Can LuminEV be used for large studies and compound screening?

Yes. The 96-well format suits large cohort studies, and the kit is sold in packs of 1, 5 or 20 plates. Because tetraspanin levels reflect EV release, it is also used to screen compounds that change EV secretion; the validation study detected suppression and induction of EV release with GW4869 and monensin.

Can LuminEV detect EV subpopulations or marker co-localization?

Yes. Because markers are measured together on the same vesicles, LuminEV can be used to profile EV subpopulations by their surface protein composition and to assess co-localization of different surface markers on the same EV.

Which species has LuminEV been tested in?

The kit has been tested with human samples.

Has LuminEV been published?

Yes. The assay is described and validated in Tordoff et al., "A novel multiplexed immunoassay for surface-exposed proteins in plasma extracellular vesicles," Journal of Extracellular Vesicles, 2024, 13(11), doi:10.1002/jev2.70007, with authors from NeuroDex, Columbia University, the National Institute on Aging (NIH) and Johns Hopkins University. In plasma from 70 disease-free donors, CD9, CD63 and CD81 made up about 72%, 16% and 12% of the tetraspanin signal.

Can I order a custom panel?

Yes. Custom panels with other EV surface markers can be developed. In the validation study, the platform also detected cell type-specific markers such as CD235a (erythrocytes), GAP43 (neurons) and CD68 (macrophages). Contact us to discuss your markers.

How much does LuminEV cost?

A single 96-well plate kit is $2,000. Packs of 5 plates are $8,000 and packs of 20 plates are $25,600. Order online or contact us for a quote.

Can LuminEV be used for diagnosis?

No. LuminEV is for research use only. It is not intended for diagnostic, therapeutic or clinical procedures.